<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 51-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/norm/high/457967-7952.jpg" HighPicHeight="102" HighPicSize="5716" HighPicWidth="300" ID="457967" LowPic="https://images.icecat.biz/img/norm/low/457967-7952.jpg" LowPicHeight="68" LowPicSize="5774" LowPicWidth="200" Name="AT-8024M" IntName="AT-8024M" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/img_457967_medium_1480929736_826_26509.jpg" Pic500x500Height="170" Pic500x500Size="23939" Pic500x500Width="500" Prod_id="AT-8024M" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/thumbs/457967.jpg" ThumbPicSize="2049" Title="Allied Telesis AT-8024M เน็ตเวิร์กสวิตช์ จัดการ รองรับเทคโนโลยี Power over Ethernet (PoE)" GeneratedIntTitle="Allied Telesis AT-8024M network switch" GeneratedLocalTitle="Allied Telesis AT-8024M เน็ตเวิร์กสวิตช์ จัดการ รองรับเทคโนโลยี Power over Ethernet (PoE)" BrandLocalTitle="">
  <CategoryFeatureGroup ID="31974" No="0">
   <FeatureGroup ID="0">
    <Name ID="9472960" langid="51" Value="รายละเอียดทางเทคนิค"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="763" No="195">
   <FeatureGroup ID="12">
    <Name ID="1873112" langid="51" Value="พอร์ตและการเชื่อมต่อ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1144" No="135">
   <FeatureGroup ID="14">
    <Name ID="1873114" langid="51" Value="น้ำหนักและขนาด"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1142" No="150">
   <FeatureGroup ID="27">
    <Name ID="1873127" langid="51" Value="กำลังไฟ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1143" No="140">
   <FeatureGroup ID="28">
    <Name ID="1935943" langid="51" Value="เงื่อนไขในการทำงาน"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2987" No="165">
   <FeatureGroup ID="34">
    <Name ID="1873132" langid="51" Value="โปรโตคอล"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1141" No="190">
   <FeatureGroup ID="35">
    <Name ID="1873133" langid="51" Value="ระบบเครือข่าย"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2484" No="180">
   <FeatureGroup ID="62">
    <Name ID="1873153" langid="51" Value="การส่งข้อมูล"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2483" No="125">
   <FeatureGroup ID="67">
    <Name ID="1873157" langid="51" Value="ข้อมูลบรรจุภัณฑ์"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2482" No="175">
   <FeatureGroup ID="75">
    <Name ID="1873165" langid="51" Value="ความปลอดภัย"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="41469" No="0">
   <FeatureGroup ID="76">
    <Name ID="1873166" langid="51" Value="ใบรับรอง"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2944" No="200">
   <FeatureGroup ID="93">
    <Name ID="1873178" langid="51" Value="คุณสมับิตการจัดการ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="49104" No="130">
   <FeatureGroup ID="116">
    <Name ID="2427256" langid="51" Value="ข้อมูลบรรจุภัณฑ์"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="5713" No="185">
   <FeatureGroup ID="137">
    <Name ID="1935961" langid="51" Value="เคเบิ้ลใยแก้วนำแสง"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53530" No="0">
   <FeatureGroup ID="143">
    <Name ID="2427250" langid="51" Value="แบตเตอรี่"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8343" No="144">
   <FeatureGroup ID="146">
    <Name ID="1935963" langid="51" Value="คุณสมบัติอื่นๆ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10881" No="160">
   <FeatureGroup ID="148">
    <Name ID="2427251" langid="51" Value="การออกแบบ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="9999" No="145">
   <FeatureGroup ID="174">
    <Name ID="1935969" langid="51" Value="การส่งกระแสไฟฟ้าเพื่อจ่ายให้กับอุปกรณ์เครือข่าย (PoE)"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10882" No="155">
   <FeatureGroup ID="184">
    <Name ID="2427257" langid="51" Value="ประสิทธิภาพ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="70398" No="0">
   <FeatureGroup ID="185">
    <Name ID="1935973" langid="51" Value="คุณสมบัติ"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="24990" No="-100">
   <FeatureGroup ID="198">
    <Name ID="1873262" langid="51" Value="ข้อมูลการส่งสินค้า"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="60022" No="0">
   <FeatureGroup ID="232">
    <Name ID="4217614" langid="51" Value="คุณสมบัติของผู้ขาย"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="27921" No="170">
   <FeatureGroup ID="252">
    <Name ID="5052395" langid="51" Value="คุณสมบัติ มัลติเคส"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76178" No="120">
   <FeatureGroup ID="279">
    <Name ID="7623063" langid="51" Value="ความยั่งยืน"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77984" No="0">
   <FeatureGroup ID="305">
    <Name ID="8856157" langid="51" Value="การปล่อยก๊าซคาร์บอนไดออกไซด์"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="258">
   <Name ID="1869011" langid="51" Value="เน็ตเวิร์กสวิตช์"/>
  </Category>
  <EANCode/>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="จัดการ" langid="51" No="1"/>
   <GeneratedBulletPoint Value="จำนวนของพอร์ตอีเธอร์เน็ต RJ-45 ในสวิตชิ่งทั่วไป: 24" langid="51" No="2"/>
   <GeneratedBulletPoint Value="100Base-TX, 10Base-T" langid="51" No="3"/>
   <GeneratedBulletPoint Value="ตารางที่อยู่ MAC: 4000 รายการ ความจุการสลับ: 9.6 Gbit/s" langid="51" No="4"/>
   <GeneratedBulletPoint Value="รองรับเทคโนโลยี Power over Ethernet (PoE)" langid="51" No="5"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription/>
  <ProductFeature Localized="0" ID="14452051" Local_ID="0" Value="Managed" CategoryFeature_ID="20904" CategoryFeatureGroup_ID="2944" No="10100150" Optional="0" Presentation_Value="จัดการ" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="จัดการ">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3769">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1945851" langid="51" Value="ชนิดของสวิตช์"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452026" Local_ID="0" Value="RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 2674, RFC 2863" CategoryFeature_ID="17379" CategoryFeatureGroup_ID="2944" No="99980" Optional="0" Presentation_Value="RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 2674, RFC 2863" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 2674, RFC 2863">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2989">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1958048" langid="51" Value="รองรับ MIB"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452013" Local_ID="0" Value="24" CategoryFeature_ID="86090" CategoryFeatureGroup_ID="763" No="10100100" Optional="0" Presentation_Value="24" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="24">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13503">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1950898" langid="51" Value="จำนวนของพอร์ตอีเธอร์เน็ต RJ-45 ในสวิตชิ่งทั่วไป"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452055" Local_ID="0" Value="IEEE 802.1d,IEEE 802.1D,IEEE 802.1p,IEEE 802.1P,IEEE 802.1Q,IEEE 802.1w,IEEE 802.1x,IEEE 802.3,IEEE 802.3ab,IEEE 802.3ac,IEEE 802.3ad,IEEE 802.3u,IEEE 802.3x" CategoryFeature_ID="45644" CategoryFeatureGroup_ID="1141" No="100999" Optional="0" Presentation_Value="IEEE 802.1d, IEEE 802.1D, IEEE 802.1p, IEEE 802.1P, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ac, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="IEEE 802.1d, IEEE 802.1D, IEEE 802.1p, IEEE 802.1P, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ac, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1802">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1957079" langid="51" Value="มาตรฐานระบบเครือข่าย"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452017" Local_ID="0" Value="100Base-TX,10Base-T" CategoryFeature_ID="2027" CategoryFeatureGroup_ID="1141" No="100099" Optional="0" Presentation_Value="100Base-TX, 10Base-T" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100Base-TX, 10Base-T">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7659">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1948000" langid="51" Value="เทคโนโลยีการเชื่อมต่อวงจรอีเธอร์เน็ตด้วยสายเคเบิ้ลทองแดง"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452042" Local_ID="0" Value="Y" CategoryFeature_ID="2042" CategoryFeatureGroup_ID="1141" No="100002" Optional="0" Presentation_Value="วาย" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="วาย">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="536">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956230" langid="51" Value="สื่อสารสองทางเต็มอัตรา"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452059" Local_ID="0" Value="Y" CategoryFeature_ID="16314" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="วาย" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="วาย">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2756">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1957848" langid="51" Value="รองรับการควบคุมการไหลของข้อมูล"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452018" Local_ID="0" Value="4000" CategoryFeature_ID="2026" CategoryFeatureGroup_ID="2484" No="10100086" Optional="0" Presentation_Value="4000 รายการ" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="4000">
    <Measure ID="56">
     <Signs>
      <Sign ID="24511" langid="51"><![CDATA[รายการ]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="566">
    <Measure ID="56" Sign="">
     <Signs>
      <Sign ID="24511" langid="51"><![CDATA[รายการ]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956246" langid="51" Value="ตารางที่อยู่ MAC"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452021" Local_ID="0" Value="9.6" CategoryFeature_ID="11205" CategoryFeatureGroup_ID="2484" No="100090" Optional="0" Presentation_Value="9.6 Gbit/s" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="9.6">
    <Measure ID="68">
     <Signs>
      <Sign ID="24522" langid="51"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1801">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="24522" langid="51"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1957078" langid="51" Value="ความจุการสลับ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452012" Local_ID="0" Value="0.1" CategoryFeature_ID="8769" CategoryFeatureGroup_ID="2484" No="100022" Optional="1" Presentation_Value="0.1 Gbit/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0.1">
    <Measure ID="68">
     <Signs>
      <Sign ID="24522" langid="51"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3188">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="24522" langid="51"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1945463" langid="51" Value="อัตราการถ่ายโอนข้อมูลสูงสุด"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452048" Local_ID="0" Value="6" CategoryFeature_ID="86116" CategoryFeatureGroup_ID="2484" No="99999" Optional="0" Presentation_Value="6 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="6">
    <Measure ID="19">
     <Signs>
      <Sign ID="24478" langid="51"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="13509">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="24478" langid="51"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1950903" langid="51" Value="หน่วยความจำของตัวพักแพ็กเก็ต"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452084" Local_ID="0" Value="UL 1950 (UL/cUL), EN60950 (TUV)" CategoryFeature_ID="2039" CategoryFeatureGroup_ID="10881" No="99902" Optional="1" Presentation_Value="UL 1950 (UL/cUL), EN60950 (TUV)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="UL 1950 (UL/cUL), EN60950 (TUV)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="607">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956273" langid="51" Value="ความปลอดภัย"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452029" Local_ID="0" Value="18" CategoryFeature_ID="6909" CategoryFeatureGroup_ID="10882" No="100002" Optional="0" Presentation_Value="18 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="18">
    <Measure ID="19">
     <Signs>
      <Sign ID="24478" langid="51"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="6">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="24478" langid="51"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1871002" langid="51" Value="หน่วยความจำภายใน"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452097" Local_ID="0" Value="200000" CategoryFeature_ID="7920" CategoryFeatureGroup_ID="10882" No="99980" Optional="0" Presentation_Value="200000 ชม." Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="200000">
    <Measure ID="46">
     <Signs>
      <Sign ID="24502" langid="51"><![CDATA[ชม.]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="533">
    <Measure ID="46" Sign="">
     <Signs>
      <Sign ID="24502" langid="51"><![CDATA[ชม.]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956228" langid="51" Value="หมายถึงเวลาระหว่างความล้มเหลว (MTBF)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452074" Local_ID="0" Value="65" CategoryFeature_ID="11195" CategoryFeatureGroup_ID="1142" No="100090" Optional="0" Presentation_Value="65 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="65">
    <Measure ID="44">
     <Signs>
      <Sign ID="24500" langid="51"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="445">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="24500" langid="51"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956163" langid="51" Value="การใช้พลังงาน (ทั่วไป)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452034" Local_ID="0" Value="Y" CategoryFeature_ID="17380" CategoryFeatureGroup_ID="9999" No="10100098" Optional="0" Presentation_Value="วาย" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="วาย">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2988">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1958047" langid="51" Value="รองรับเทคโนโลยี Power over Ethernet (PoE)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452068" Local_ID="0" Value="Web, CLI, Telnet, Serial, SNMP v1 &amp; v2c, RMON 1" CategoryFeature_ID="2035" CategoryFeatureGroup_ID="8343" No="119333" Optional="1" Presentation_Value="Web, CLI, Telnet, Serial, SNMP v1 &amp; v2c, RMON 1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Web, CLI, Telnet, Serial, SNMP v1 &amp; v2c, RMON 1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="665">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956317" langid="51" Value="แพลตฟอร์มการจัดการ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452045" Local_ID="0" Value="8/15 ms" CategoryFeature_ID="2032" CategoryFeatureGroup_ID="8343" No="100500" Optional="1" Presentation_Value="8/15 ms" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8/15 ms">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="491">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956198" langid="51" Value="ความล่าช้า"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452019" Local_ID="0" Value="100" CategoryFeature_ID="8500" CategoryFeatureGroup_ID="8343" No="100060" Optional="1" Presentation_Value="100 Mbit/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100">
    <Measure ID="23">
     <Signs>
      <Sign ID="24482" langid="51"><![CDATA[Mbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1774">
    <Measure ID="23" Sign="">
     <Signs>
      <Sign ID="24482" langid="51"><![CDATA[Mbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1957059" langid="51" Value="อัตราความเร็วในการถ่ายโอนข้อมูล"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452036" Local_ID="0" Value="438 x 222 x 44" CategoryFeature_ID="5038" CategoryFeatureGroup_ID="8343" No="100050" Optional="1" Presentation_Value="438 x 222 x 44 มม." Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="438 x 222 x 44">
    <Measure ID="24">
     <Signs>
      <Sign ID="24483" langid="51"><![CDATA[มม.]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="49">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="24483" langid="51"><![CDATA[มม.]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956132" langid="51" Value="ขนาด ( กว้าง x ยาว x สูง )"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452020" Local_ID="0" Value="Wired" CategoryFeature_ID="8501" CategoryFeatureGroup_ID="8343" No="100044" Optional="1" Presentation_Value="มีสาย" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="มีสาย">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1655">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956973" langid="51" Value="เทคโนโลยีของการเชื่อมต่อ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452071" Local_ID="0" Value="148.800 pps" CategoryFeature_ID="7923" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="148.800 pps" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="148.800 pps">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1814">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5617" langid="1" Value="Packet transfer speed"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452077" Local_ID="0" Value="100-240V, 50/60Hz" CategoryFeature_ID="8356" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="100-240V, 50/60Hz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100-240V, 50/60Hz">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="780">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956405" langid="51" Value="ข้อกำหนดการใช้พลังงาน"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452025" Local_ID="0" Value="Ethernet, Fast Ethernet" CategoryFeature_ID="14266" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="Ethernet, Fast Ethernet" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Ethernet, Fast Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1104">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956621" langid="51" Value="เครือข่ายคุณสมบัติ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452090" Local_ID="0" Value="0 - 40" CategoryFeature_ID="7827" CategoryFeatureGroup_ID="1143" No="100040" Optional="0" Presentation_Value="0 - 40 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 40">
    <Measure ID="65">
     <Signs>
      <Sign ID="24519" langid="51"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="24519" langid="51"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956627" langid="51" Value="อุณหภูมิในการทำงาน (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452089" Local_ID="0" Value="-25 - 70" CategoryFeature_ID="7830" CategoryFeatureGroup_ID="1143" No="100039" Optional="0" Presentation_Value="-25 - 70 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-25 - 70">
    <Measure ID="65">
     <Signs>
      <Sign ID="24519" langid="51"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="24519" langid="51"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956387" langid="51" Value="อุณหภูมิในการเก็บ (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452088" Local_ID="0" Value="5 - 95" CategoryFeature_ID="7825" CategoryFeatureGroup_ID="1143" No="100035" Optional="0" Presentation_Value="5 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="2427386" langid="51" Value="ความชื้นสัมพัทธ์ที่เครื่องทำงาน (H-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452091" Local_ID="0" Value="5 - 95" CategoryFeature_ID="12190" CategoryFeatureGroup_ID="1143" No="100034" Optional="0" Presentation_Value="5 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1956789" langid="51" Value="การจัดเก็บความชื้นสัมพัทธ์ (R-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452037" Local_ID="0" Value="3500" CategoryFeature_ID="8713" CategoryFeatureGroup_ID="1144" No="100000" Optional="0" Presentation_Value="3.5 กก." Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3.5">
    <Measure ID="17">
     <Signs>
      <Sign ID="24476" langid="51"><![CDATA[กก.]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="94">
    <Measure ID="38" Sign="">
     <Signs>
      <Sign ID="24494" langid="51"><![CDATA[กรัม]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1871018" langid="51" Value="น้ำหนัก"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452047" Local_ID="0" Value="1x" CategoryFeature_ID="10133" CategoryFeatureGroup_ID="8343" No="3" Optional="1" Presentation_Value="1x" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1x">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1586">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956920" langid="51" Value="การขยายล็อต"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452024" Local_ID="0" Value="24x 10/100 Ethernet&#10;1x RS-232 Console&#10;1x Power" CategoryFeature_ID="6908" CategoryFeatureGroup_ID="8343" No="0" Optional="1" Presentation_Value="24x 10/100 Ethernet&#10;1x RS-232 Console&#10;1x Power" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="24x 10/100 Ethernet&#10;1x RS-232 Console&#10;1x Power">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="470">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2427379" langid="51" Value="พอร์ตเชื่อมต่อข้อมูล Input/Output"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="14452099" Local_ID="0" Value="FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, EN61000-3-2, EN61000-3-3" CategoryFeature_ID="11201" CategoryFeatureGroup_ID="8343" No="0" Optional="1" Presentation_Value="FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, EN61000-3-2, EN61000-3-3" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, EN61000-3-2, EN61000-3-3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="803">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1956420" langid="51" Value="คลื่นแม่เหล็กไฟฟ้า"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/norm/low/457967-7952.jpg" LowPicHeight="68" LowPicWidth="200" LowSize="5774" No="1" Original="https://images.icecat.biz/img/norm/high/457967-7952.jpg" OriginalSize="5716" Pic="https://images.icecat.biz/img/norm/high/457967-7952.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/img_457967_medium_1480929736_826_26509.jpg" Pic500x500Height="170" Pic500x500Size="23939" Pic500x500Width="500" PicHeight="102" PicWidth="300" ProductPicture_ID="13397110" Size="5716" ThumbPic="https://images.icecat.biz/thumbs/457967.jpg" ThumbSize="2049" Type="ProductImage" UpdatedDate="2019-04-04 05:51:37"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-06-07 13:34:54" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="51" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=457967&amp;lang=th" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="51">Allied Telesis AT-8024M, จัดการ, สื่อสารสองทางเต็มอัตรา, รองรับเทคโนโลยี Power over Ethernet (PoE)</ShortSummaryDescription>
   <LongSummaryDescription langid="51">Allied Telesis AT-8024M. ชนิดของสวิตช์: จัดการ. จำนวนของพอร์ตอีเธอร์เน็ต RJ-45 ในสวิตชิ่งทั่วไป: 24. สื่อสารสองทางเต็มอัตรา. ตารางที่อยู่ MAC: 4000 รายการ, ความจุการสลับ: 9.6 Gbit/s. มาตรฐานระบบเครือข่าย: IEEE 802.1d, IEEE 802.1D, IEEE 802.1p, IEEE 802.1P, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1x, IEEE.... รองรับเทคโนโลยี Power over Ethernet (PoE)</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="49" Name="Allied Telesis"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/717606c6-0ec4-467b-959c-4b2ce9330376" URL="https://coc.icecat.biz/717606c6-0ec4-467b-959c-4b2ce9330376"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
