<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 14-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/gallery/30e54be428d3f3b887168e02f8fd019fca54b3fe.jpg" HighPicHeight="5000" HighPicSize="1772361" HighPicWidth="5000" ID="80305432" LowPic="https://images.icecat.biz/img/gallery_lows/8d66c83dd84757dcb71d2c8bb02932da19a3e8be.jpg" LowPicHeight="200" LowPicSize="6273" LowPicWidth="200" Name="R440" IntName="R440" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/8dedc29aa2bbcd20de21e9da23ec28febab08480.jpg" Pic500x500Height="500" Pic500x500Size="27782" Pic500x500Width="500" Prod_id="PER440PL2001" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/3278fc6f1f35fe7e35bb5bae2c376528f1b6b0b5.jpg" ThumbPicSize="1749" Title="DELL PowerEdge R440 serwer 480 GB Rack (1U) Intel® Xeon Silver 4210R 2,4 GHz 16 GB DDR4-SDRAM 550 W" GeneratedIntTitle="DELL PowerEdge R440 server" GeneratedLocalTitle="DELL PowerEdge R440 serwer 480 GB Rack (1U) Intel® Xeon Silver 4210R 2,4 GHz 16 GB DDR4-SDRAM 550 W" BrandLocalTitle="">
  <CategoryFeatureGroup ID="10891" No="-80">
   <FeatureGroup ID="0">
    <Name ID="9454491" langid="14" Value="Szczegóły techniczne"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1051" No="100">
   <FeatureGroup ID="1">
    <Name ID="1222494" langid="14" Value="Procesor"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1049" No="90">
   <FeatureGroup ID="3">
    <Name ID="521434" langid="14" Value="Pamięć"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2697" No="20">
   <FeatureGroup ID="5">
    <Name ID="521436" langid="14" Value="Wyświetlacz"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1053" No="50">
   <FeatureGroup ID="12">
    <Name ID="5785736" langid="14" Value="Porty i interfejsy"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1055" No="-5">
   <FeatureGroup ID="14">
    <Name ID="521444" langid="14" Value="Waga i rozmiary"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1056" No="10">
   <FeatureGroup ID="27">
    <Name ID="5785729" langid="14" Value="Moc"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2698" No="5">
   <FeatureGroup ID="28">
    <Name ID="5785724" langid="14" Value="Warunki pracy"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1054" No="60">
   <FeatureGroup ID="35">
    <Name ID="5785710" langid="14" Value="Sieć"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8609" No="80">
   <FeatureGroup ID="47">
    <Name ID="5785672" langid="14" Value="Nośnik danych"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="23800" No="-10">
   <FeatureGroup ID="67">
    <Name ID="5785699" langid="14" Value="Dane opakowania"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2695" No="3">
   <FeatureGroup ID="76">
    <Name ID="5785731" langid="14" Value="Certyfikaty"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="11644" No="15">
   <FeatureGroup ID="90">
    <Name ID="521514" langid="14" Value="Oprogramowanie"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="7714" No="-20">
   <FeatureGroup ID="116">
    <Name ID="521539" langid="14" Value="Zawartość opakowania"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="4192" No="40">
   <FeatureGroup ID="124">
    <Name ID="5785684" langid="14" Value="Gniazda rozszerzeń"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53421" No="0">
   <FeatureGroup ID="143">
    <Name ID="1079880" langid="14" Value="Bateria"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8611" No="-100">
   <FeatureGroup ID="146">
    <Name ID="5785703" langid="14" Value="Pozostałe funkcje"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10890" No="30">
   <FeatureGroup ID="148">
    <Name ID="5785680" langid="14" Value="Konstrukcja"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8610" No="70">
   <FeatureGroup ID="163">
    <Name ID="764426" langid="14" Value="Grafika"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="12136" No="13">
   <FeatureGroup ID="183">
    <Name ID="5785705" langid="14" Value="Cechy szczególne procesora"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10889" No="25">
   <FeatureGroup ID="184">
    <Name ID="5785704" langid="14" Value="Wydajność"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="20049" No="-70">
   <FeatureGroup ID="185">
    <Name ID="5785697" langid="14" Value="Cechy"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="35829" No="0">
   <FeatureGroup ID="198">
    <Name ID="2216971" langid="14" Value="Dane logistyczne"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="59907" No="0">
   <FeatureGroup ID="232">
    <Name ID="4023558" langid="14" Value="Cechy dostawcy"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76092" No="0">
   <FeatureGroup ID="279">
    <Name ID="7392251" langid="14" Value="Zrównoważony rozwój"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77982" No="0">
   <FeatureGroup ID="305">
    <Name ID="8842937" langid="14" Value="Ślad węglowy"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="156">
   <Name ID="3874339" langid="14" Value="Serwery"/>
  </Category>
  <EANCode/>
  <FeatureLogo ID="1498" Feature_ID="2196" Value="Intel Xeon Silver" LogoPic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Width="0" Height="0" Size="0">
   <Descriptions>
    <Description ID="6189" langid="14">Procesory Intel® Xeon® zapewniają przetwarzanie w chmurze, analizę w czasie rzeczywistym, przetwarzanie kluczowych procesów biznesowych oraz wgląd w big data. Zwiększ wydajność i niezawodność centrum danych, aby sprostać dowolnemu obciążeniu.</Description>
   </Descriptions>
   <FeatureLogoFeatures>
    <FeatureLogoFeature ID="2196">
     <FeatureLogoValues>
      <FeatureLogoValue ID="6638">Intel Xeon Silver</FeatureLogoValue>
     </FeatureLogoValues>
    </FeatureLogoFeature>
   </FeatureLogoFeatures>
  </FeatureLogo>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy>
   <ReasonToBuy ID="93679495" Value="Poznaj doskonałą równowagę między wydajnością i gęstością w skalowalnym systemie komputerowym. Serwer PowerEdge R440 zapewnia wiele korzyści w niewielkiej obudowie. Skorzystaj z zalet elastycznej platformy i zmaksymalizuj wydajność dzięki dwóm procesorom skalowalnym Intel® Xeon®, obsłudze nawet 16 modułów DIMM i skalowalnej pamięci masowej, która umożliwia łączenie dysków SSD i NVMe PCIe. Wbudowane narzędzia diagnostyczne i usługa SupportAssist zapewniają maksymalny czas pracy serwera R440 bez przestojów i jego bezproblemowe działanie. Idealne obciążenia robocze: -HPC&lt;br&gt;-Technologie WWW&lt;br&gt;-Infrastruktura skalowalna" HighPic="https://images.icecat.biz/img/bullets/80305432-5f0ef71910ba7369363237.jpg" HighPicSize="0" No="1" Title="Wydajność i gęstość w 2-procesorowym serwerze 1U" langid="14" origin="RTB" IsRich="0"/>
   <ReasonToBuy ID="93679496" Value="Nowoczesne platformy komputerowe firmy Dell są łatwe w skalowaniu i oferują technologie maksymalizujące wydajność aplikacji. Serwer PowerEdge R440 montowany w szafie serwerowej zapewnia swobodę wyboru i elastyczność na potrzeby optymalizacji wydajności i gęstości. -Procesory skalowalne Intel® Xeon® mają o 27% więcej rdzeni obliczeniowych, co przekłada się na 50-procentowy wzrost przepustowości w porównaniu z procesorami poprzedniej generacji3.&lt;br&gt;-Możesz zwiększyć elastyczność pamięci masowej dzięki nawet 10 dyskom SAS/SATA/SSD 2,5&quot; z maks. 4 dyskami SSD PCIe NVMe lub 4 napędami 3,5&quot;.&lt;br&gt;-Dyski SSD M.2 zoptymalizowane pod kątem rozruchu zapewniają więcej miejsca w pamięci masowej." HighPic="https://images.icecat.biz/img/bullets/80305432-5f0ef719c2aa6506662453.jpg" HighPicSize="0" No="2" Title="Wydajność i skalowalność dzięki ofercie serwerów PowerEdge" langid="14" origin="RTB" IsRich="0"/>
   <ReasonToBuy ID="93679497" Value="Inteligentne funkcje optymalizacji oprogramowania Dell OpenManage pozwalają ograniczyć czas poświęcany na rutynową konserwację i przeznaczyć go na ważniejsze cele. -Ograniczając przestoje dzięki proaktywnej diagnostyce i automatycznemu rozwiązywaniu problemów, można poprawić produktywność nawet o 90%4&lt;br&gt;-Dzięki integracji z rozwiązaniami VMware® vSphere®, Microsoft® System Center i Nagios® można z powodzeniem korzystać z istniejących konsoli do zarządzania.&lt;br&gt;-Niewymagający agentów kontroler Dell iDRAC9 umożliwia zautomatyzowane, wydajne zarządzanie.&lt;br&gt;-Możesz uprościć wdrażanie dzięki konsoli OpenManage nowej generacji i profilom serwera, aby szybko skonfigurować oraz przygotować serwery w sposób ułatwiający skalowanie." HighPic="https://images.icecat.biz/img/bullets/80305432-5f0ef71a5051a972895831.jpg" HighPicSize="0" No="3" Title="Lepsza produktywność dzięki inteligentnym wbudowanym funkcjom zarządzania" langid="14" origin="RTB" IsRich="0"/>
   <ReasonToBuy ID="93679498" Value="Kompleksowa, odporna na ataki internetowe architektura z wbudowanymi zabezpieczeniami gwarantuje skuteczną ochronę danych. -Nowa funkcja blokady konfiguracji serwerów i oprogramowania wewnętrznego pozwala uchronić się od zmian mogących zakłócić prawidłowe działanie systemu.&lt;br&gt;-Korzystając z funkcji wymazywania systemu lokalnej pamięci masowej, można skutecznie uchronić się przed naruszeniem prywatności danych w razie zmiany przeznaczenia serwerów lub wycofania ich z eksploatacji.&lt;br&gt;-Mechanizm automatycznych aktualizacji sprawdza zależności plików oraz wyznacza właściwą kolejność wprowadzania poprawek przed ich wdrożeniem — niezależnie od systemu operacyjnego i monitora maszyn wirtualnych.&lt;br&gt;-Wbudowane uwierzytelnianie pozwala przejąć kontrolę nad konsolami oprogramowania wewnętrznego. Dzięki temu uruchamiane są tylko aktualizacje prawidłowo zaprojektowane do obsługi oprogramowania wewnętrznego." HighPic="https://images.icecat.biz/img/bullets/80305432-5f0ef71ae16ff687073962.jpg" HighPicSize="0" No="4" Title="Wzmocnij centrum danych dzięki kompleksowej ochronie" langid="14" origin="RTB" IsRich="0"/>
  </ReasonsToBuy>
  <BulletPoints>
   <BulletPoint Value="No OS" langid="14" No="1"/>
   <BulletPoint Value="Intel Xeon Silver 4210R (13.75MB Cache, 2.4GHz)" langid="14" No="2"/>
   <BulletPoint Value="16GB (3200MHz) DDR4-SDRAM (1 x 16) &amp; 480GB SSD" langid="14" No="3"/>
   <BulletPoint Value="iDRAC9 Enterprise" langid="14" No="4"/>
  </BulletPoints>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Intel® Xeon Silver 4210R 2,4 GHz" langid="14" No="1"/>
   <GeneratedBulletPoint Value="16 GB 3200 MHz DDR4-SDRAM 1 x 16" langid="14" No="2"/>
   <GeneratedBulletPoint Value="480 GB DVD-RW" langid="14" No="3"/>
   <GeneratedBulletPoint Value="Rack (1U) 550 W" langid="14" No="4"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription ID="73564647" LongDesc="&lt;b&gt;Serwer zaprojektowany z myślą o gęstości i skalowalnym przetwarzaniu&lt;/b&gt;&lt;br&gt;Zyskaj wyższą wydajność i gęstość z kompaktowym 2-procesorowym serwerem 1U do montażu w szafie serwerowej na potrzeby środowisk HPC, technologii WWW i skalowalnej infrastruktury." ManualPDFSize="0" ManualPDFURL="" MiddleDesc="" PDFSize="0" PDFURL="" ShortDesc="Intel Xeon Silver 4210R (13.75MB Cache, 2.4GHz), 16GB DDR4-SDRAM (3200MT/s RDIMM Dual Rank), 480GB SSD, DVD-RW, LAN, PERC H730P 2GB, iDRAC9 Enterprise, 550W, No OS" URL="https://www.dell.com/pl/firmiinstytucji/p/poweredge-r440/pd" WarrantyInfo="3 Lata Basic Onsite" langid="14"/>
  <Disclaimers>
   <Disclaimer langid="14" value="Rzeczywista konfiguracja może różnić się od tej przedstawionej na ilustracji"/>
  </Disclaimers>
  <ProductFamily ID="63717" LowPic="" ThumbPic="">
   <Name ID="949457" langid="1" Value="PowerEdge"/>
  </ProductFamily>
  <ProductFeature Localized="0" ID="362943444" Local_ID="0" Value="Intel Xeon Silver" CategoryFeature_ID="11563" CategoryFeatureGroup_ID="1051" No="10100400" Optional="0" Presentation_Value="Intel® Xeon Silver" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Intel® Xeon Silver">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2196">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519864" langid="14" Value="Typ procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943450" Local_ID="0" Value="Intel" CategoryFeature_ID="4443" CategoryFeatureGroup_ID="1051" No="10213006" Optional="0" Presentation_Value="Intel" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Intel">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1013">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519724" langid="14" Value="Producent procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943440" Local_ID="0" Value="4210R" CategoryFeature_ID="1239" CategoryFeatureGroup_ID="1051" No="100398" Optional="0" Presentation_Value="4210R" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="4210R">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="47">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519557" langid="14" Value="Model procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943438" Local_ID="0" Value="2.4" CategoryFeature_ID="73717" CategoryFeatureGroup_ID="1051" No="100396" Optional="0" Presentation_Value="2,4 GHz" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2,4">
    <Measure ID="37">
     <Signs>
      <Sign ID="7610" langid="14"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11379">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="7610" langid="14"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1854061" langid="14" Value="Taktowanie procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="458708943" Local_ID="0" Value="Intel Xeon Scalable 2nd Gen" CategoryFeature_ID="893918" CategoryFeatureGroup_ID="1051" No="100400" Optional="0" Presentation_Value="Skalowalne Intel® Xeon® drugiej generacji" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Skalowalne Intel® Xeon® drugiej generacji">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="44870">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="8075884" langid="14" Value="Generowanie procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943442" Local_ID="0" Value="3.2" CategoryFeature_ID="72626" CategoryFeatureGroup_ID="1051" No="100395" Optional="0" Presentation_Value="3,2 GHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3,2">
    <Measure ID="37">
     <Signs>
      <Sign ID="7610" langid="14"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7978">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="7610" langid="14"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1854059" langid="14" Value="Maksymalne taktowanie procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943441" Local_ID="0" Value="10" CategoryFeature_ID="31274" CategoryFeatureGroup_ID="1051" No="100300" Optional="0" Presentation_Value="10" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6089">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516602" langid="14" Value="Liczba rdzeni procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943452" Local_ID="0" Value="13.75" CategoryFeature_ID="135262" CategoryFeatureGroup_ID="1051" No="100290" Optional="0" Presentation_Value="13,75 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="13,75">
    <Measure ID="19">
     <Signs>
      <Sign ID="15509" langid="14"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10041">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="15509" langid="14"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1078559" langid="14" Value="Cache procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942045" Local_ID="0" Value="1" CategoryFeature_ID="1280" CategoryFeatureGroup_ID="1051" No="100090" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="596">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516187" langid="14" Value="Liczba procesorów"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="375221858" Local_ID="0" Value="85" CategoryFeature_ID="135036" CategoryFeatureGroup_ID="1051" No="100010" Optional="1" Presentation_Value="85 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="85">
    <Measure ID="44">
     <Signs>
      <Sign ID="7617" langid="14"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11778">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="7617" langid="14"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1163613" langid="14" Value="Termiczny układ zasilania (TDP)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="369939798" Local_ID="0" Value="LGA 3647 (Socket P)" CategoryFeature_ID="39841" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="LGA 3647 (Socket P)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="LGA 3647 (Socket P)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2325">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519954" langid="14" Value="Gniazdo procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="369831422" Local_ID="0" Value="14" CategoryFeature_ID="134949" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="14 nm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="14">
    <Measure ID="98">
     <Signs>
      <Sign ID="7667" langid="14"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1623">
    <Measure ID="98" Sign="">
     <Signs>
      <Sign ID="7667" langid="14"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1854057" langid="14" Value="Litografia procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="370495886" Local_ID="0" Value="20" CategoryFeature_ID="134950" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="20" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="20">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1076054" langid="14" Value="Liczba wątków"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="371929035" Local_ID="0" Value="64-bit" CategoryFeature_ID="134951" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="64-bit" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="64-bit">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7975">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1076632" langid="14" Value="Tryb pracy procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="376248600" Local_ID="0" Value="Cascade Lake" CategoryFeature_ID="134956" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Cascade Lake" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Cascade Lake">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18767">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1854702" langid="14" Value="Nazwa kodowa procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="374465359" Local_ID="0" Value="78" CategoryFeature_ID="134958" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="78 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="78">
    <Measure ID="65">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10278">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="884664" langid="14" Value="Tcase"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="377511772" Local_ID="0" Value="1024" CategoryFeature_ID="134998" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="1 TB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="159">
     <Signs>
      <Sign ID="7723" langid="14"><![CDATA[TB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21987">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1855957" langid="14" Value="Maksymalna pamięć wewnętrzna wspierana przez procesor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="377575315" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="134999" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21994">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1855958" langid="14" Value="Typy pamięci wspierane przez procesor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="377647550" Local_ID="0" Value="2400" CategoryFeature_ID="135000" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="2400 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2400">
    <Measure ID="18">
     <Signs>
      <Sign ID="15508" langid="14"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21995">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="15508" langid="14"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1855959" langid="14" Value="Taktowanie zegara pamięci wspierane przez procesor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="373302319" Local_ID="0" Value="Y" CategoryFeature_ID="135019" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10196">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="880010" langid="14" Value="Technologia Execute Disable Bit (EDB)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="376559405" Local_ID="0" Value="48" CategoryFeature_ID="135023" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="48" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="48">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="20905">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1855403" langid="14" Value="Maksymalna liczba linii PCI Express"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="378281304" Local_ID="0" Value="76.0 x 56.5" CategoryFeature_ID="135025" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="76.0 x 56.5 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="76.0 x 56.5">
    <Measure ID="24">
     <Signs>
      <Sign ID="7600" langid="14"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="22011">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="7600" langid="14"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1855972" langid="14" Value="Wielkość opakowania procesora"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="370128690" Local_ID="0" Value="AVX-512" CategoryFeature_ID="135026" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="AVX-512" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="AVX-512">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3260">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="520365" langid="14" Value="Instrukcje obsługiwania"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="374190103" Local_ID="0" Value="2S" CategoryFeature_ID="135028" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="2S" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2S">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10265">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1078749" langid="14" Value="Skalowalność"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="374921111" Local_ID="0" Value="Y" CategoryFeature_ID="135032" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10283">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1078759" langid="14" Value="Wbudowane opcje dostępne"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942041" Local_ID="0" Value="16" CategoryFeature_ID="73754" CategoryFeatureGroup_ID="1049" No="10100200" Optional="0" Presentation_Value="16 GB" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="16">
    <Measure ID="20">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11381">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1079705" langid="14" Value="Pamięć wewnętrzna"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942049" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="4437" CategoryFeatureGroup_ID="1049" No="10100198" Optional="0" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="427">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519584" langid="14" Value="Typ pamięci wewnętrznej"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942047" Local_ID="0" Value="160" CategoryFeature_ID="4705" CategoryFeatureGroup_ID="1049" No="99990" Optional="0" Presentation_Value="160 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="160">
    <Measure ID="20">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1452">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519761" langid="14" Value="Maksymalna pojemność pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942040" Local_ID="0" Value="Registered (buffered)" CategoryFeature_ID="324317" CategoryFeatureGroup_ID="1049" No="100006" Optional="1" Presentation_Value="Registered (buffered)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Registered (buffered)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="38209">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5410811" langid="14" Value="Typ pamięci buforowej"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942051" Local_ID="0" Value="2" CategoryFeature_ID="324316" CategoryFeatureGroup_ID="1049" No="100005" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="8216">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1076855" langid="14" Value="Ranking pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942046" Local_ID="0" Value="16" CategoryFeature_ID="5722" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="16" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="672">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519620" langid="14" Value="Gniazda pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858074" Local_ID="0" Value="3200" CategoryFeature_ID="31277" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="3200 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3200">
    <Measure ID="18">
     <Signs>
      <Sign ID="15508" langid="14"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2900">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="15508" langid="14"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519964" langid="14" Value="Prędkość zegara pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942043" Local_ID="0" Value="1 x 16" CategoryFeature_ID="73739" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="1 x 16 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1 x 16">
    <Measure ID="20">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11380">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1079704" langid="14" Value="Układ pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942044" Local_ID="0" Value="3200" CategoryFeature_ID="291908" CategoryFeatureGroup_ID="1049" No="99999" Optional="1" Presentation_Value="3200 MT/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3200">
    <Measure ID="340">
     <Signs>
      <Sign ID="31329" langid="14"><![CDATA[MT/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="37536">
    <Measure ID="340" Sign="">
     <Signs>
      <Sign ID="31329" langid="14"><![CDATA[MT/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="5169314" langid="14" Value="Szybkość przesyłania danych pamięci"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942050" Local_ID="0" Value="480" CategoryFeature_ID="18867" CategoryFeatureGroup_ID="8609" No="213001" Optional="0" Presentation_Value="480 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="480">
    <Measure ID="20">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3318">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519991" langid="14" Value="Całkowita pojemność przechowywania"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942054" Local_ID="0" Value="N" CategoryFeature_ID="41696" CategoryFeatureGroup_ID="8609" No="100820" Optional="0" Presentation_Value="Nie" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Nie">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7335">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="520771" langid="14" Value="Usługa RAID"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942078" Local_ID="0" Value="DVD-RW" CategoryFeature_ID="5723" CategoryFeatureGroup_ID="8609" No="100000" Optional="0" Presentation_Value="DVD-RW" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="DVD-RW">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1120">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519803" langid="14" Value="Napędy optyczne"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942067" Local_ID="0" Value="4" CategoryFeature_ID="28496" CategoryFeatureGroup_ID="8609" No="100925" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3392">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148789" langid="14" Value="Liczba obsługiwanych HDD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942062" Local_ID="0" Value="3.5" CategoryFeature_ID="66074" CategoryFeatureGroup_ID="8609" No="100924" Optional="0" Presentation_Value="3.5&quot;" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3.5">
    <Measure ID="16">
     <Signs>
      <Sign ID="15507" langid="14"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7140">
    <Measure ID="16" Sign="">
     <Signs>
      <Sign ID="15507" langid="14"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
    <Name ID="517045" langid="14" Value="Obsługiwane rozmiary dysków twardych"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942055" Local_ID="0" Value="1" CategoryFeature_ID="66562" CategoryFeatureGroup_ID="8609" No="100920" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7682">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="594901" langid="14" Value="Liczba zainstalowanych dysków SSD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942057" Local_ID="0" Value="480" CategoryFeature_ID="66558" CategoryFeatureGroup_ID="8609" No="100919" Optional="0" Presentation_Value="480 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="480">
    <Measure ID="20">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="5586">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="15510" langid="14"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="520013" langid="14" Value="Pojemność pamięci SSD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942063" Local_ID="0" Value="SATA III" CategoryFeature_ID="66560" CategoryFeatureGroup_ID="8609" No="100917" Optional="0" Presentation_Value="SATA III" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="SATA III">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="5584">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="520011" langid="14" Value="Interfejs pamięci SSD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="384593311" Local_ID="0" Value="2.5&quot;" CategoryFeature_ID="593945" CategoryFeatureGroup_ID="8609" No="100916" Optional="0" Presentation_Value="2.5&quot;" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.5&quot;">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="42233">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="6891623" langid="14" Value="Rozmiar SSD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858333" Local_ID="0" Value="2.5&quot;,3.5&quot;" CategoryFeature_ID="708919" CategoryFeatureGroup_ID="8609" No="100916" Optional="0" Presentation_Value="2.5&quot;, 3.5&quot;" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.5&quot;, 3.5&quot;">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="43292">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7850356" langid="14" Value="Obsługiwane rozmiary dysków SSD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942079" Local_ID="0" Value="PERC H730P 2GB" CategoryFeature_ID="166992" CategoryFeatureGroup_ID="8609" No="100800" Optional="0" Presentation_Value="PERC H730P 2GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="PERC H730P 2GB">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="26528">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2355600" langid="14" Value="Obsługiwane kontrolery RAID"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362944032" Local_ID="0" Value="Y" CategoryFeature_ID="18290" CategoryFeatureGroup_ID="8609" No="100700" Optional="0" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2378">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516371" langid="14" Value="Obsługa podłączania podczas pracy"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942070" Local_ID="0" Value="Y" CategoryFeature_ID="41697" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1347">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516294" langid="14" Value="Przewodowa sieć LAN"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362945093" Local_ID="0" Value="10/100/1000Base-T(X)" CategoryFeature_ID="56945" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="10/100/1000Base-T(X)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000Base-T(X)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="747">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519629" langid="14" Value="Technologia okablowania"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942066" Local_ID="0" Value="Gigabit Ethernet" CategoryFeature_ID="58780" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Gigabit Ethernet" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Gigabit Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7484">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1076193" langid="14" Value="Rodzaj interfejsu sieci Ethernet"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942072" Local_ID="0" Value="2" CategoryFeature_ID="16225" CategoryFeatureGroup_ID="1053" No="101000" Optional="0" Presentation_Value="2" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2312">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519840" langid="14" Value="Ilość portów Ethernet LAN (RJ-45)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942074" Local_ID="0" Value="1" CategoryFeature_ID="17114" CategoryFeatureGroup_ID="1053" No="100500" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2308">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519940" langid="14" Value="Liczba portów USB 2.0"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942068" Local_ID="0" Value="3" CategoryFeature_ID="138415" CategoryFeatureGroup_ID="1053" No="100490" Optional="0" Presentation_Value="3" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="22701">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2213807" langid="14" Value="Ilość portów USB 3.2 Gen 1 (3.1 Gen 1) Typu-A"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942069" Local_ID="0" Value="2" CategoryFeature_ID="16223" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2323">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519953" langid="14" Value="Liczba portów VGA (D-Sub)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942077" Local_ID="0" Value="1" CategoryFeature_ID="17113" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519850" langid="14" Value="Szeregowe porty komunikacyjne"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="370526274" Local_ID="0" Value="3.0" CategoryFeature_ID="46575" CategoryFeatureGroup_ID="4192" No="100000" Optional="1" Presentation_Value="3.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7825">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1076510" langid="14" Value="Wersja gniazd typu Slot (PCI Express)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942075" Local_ID="0" Value="Rack (1U)" CategoryFeature_ID="1235" CategoryFeatureGroup_ID="10890" No="10113007" Optional="0" Presentation_Value="Rack (1U)" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Rack (1U)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="734">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519626" langid="14" Value="Obudowa"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942076" Local_ID="0" Value="Black" CategoryFeature_ID="256494" CategoryFeatureGroup_ID="10890" No="100100" Optional="0" Presentation_Value="Czarny" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Czarny">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1766">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519899" langid="14" Value="Kolor produktu"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362944312" Local_ID="0" Value="Y" CategoryFeature_ID="7105" CategoryFeatureGroup_ID="10890" No="100000" Optional="0" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="483">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516178" langid="14" Value="Możliwości montowania w stelażu"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362945462" Local_ID="0" Value="Y" CategoryFeature_ID="66072" CategoryFeatureGroup_ID="10890" No="100000" Optional="0" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10364">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1078815" langid="14" Value="Relingi"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942081" Local_ID="0" Value="iDRAC9 Enterprise" CategoryFeature_ID="1259" CategoryFeatureGroup_ID="10889" No="113025" Optional="0" Presentation_Value="iDRAC9 Enterprise" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="iDRAC9 Enterprise">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="494">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="520694" langid="14" Value="Zdalna administracja"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942080" Local_ID="0" Value="N" CategoryFeature_ID="20423" CategoryFeatureGroup_ID="11644" No="100090" Optional="0" Presentation_Value="Nie" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Nie">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3233">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519988" langid="14" Value="Zainstalowany system operacyjny"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942085" Local_ID="0" Value="- Canonical Ubuntu LTS&#10;- Citrix XenServer&#10;- Microsoft Windows Server with Hyper-V&#10;- Red Hat Enterprise Linux&#10;- SUSE Linux Enterprise Server&#10;- VMware ESXi" CategoryFeature_ID="1289" CategoryFeatureGroup_ID="11644" No="100085" Optional="0" Presentation_Value="- Canonical Ubuntu LTS&#10;- Citrix XenServer&#10;- Microsoft Windows Server with Hyper-V&#10;- Red Hat Enterprise Linux&#10;- SUSE Linux Enterprise Server&#10;- VMware ESXi" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="- Canonical Ubuntu LTS&#10;- Citrix XenServer&#10;- Microsoft Windows Server with Hyper-V&#10;- Red Hat Enterprise Linux&#10;- SUSE Linux Enterprise Server&#10;- VMware ESXi">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2507">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="519958" langid="14" Value="System operacyjny"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="373166456" Local_ID="0" Value="Y" CategoryFeature_ID="105685" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10195">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1078689" langid="14" Value="Technologia Udoskonalona Intel SpeedStep"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="375995428" Local_ID="0" Value="Y" CategoryFeature_ID="131546" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18653">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234859" langid="14" Value="Technologia Wirtualizacji Intel® (Directed I/O) (VT-d)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="372342435" Local_ID="0" Value="Y" CategoryFeature_ID="134961" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9672">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234870" langid="14" Value="Technologia Intel® Hyper Threading (Intel® HT Technology)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="372461748" Local_ID="0" Value="2.0" CategoryFeature_ID="134965" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="2.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9733">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234852" langid="14" Value="Technologia Intel® Turbo Boost"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="373035283" Local_ID="0" Value="Y" CategoryFeature_ID="134975" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10194">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234866" langid="14" Value="Nowe instrukcje AES (Intel® AES-NI)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="373776123" Local_ID="0" Value="Y" CategoryFeature_ID="134979" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10200">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234848" langid="14" Value="Technologia Intel® Trusted Execution"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="374783275" Local_ID="0" Value="Y" CategoryFeature_ID="134981" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10282">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234861" langid="14" Value="Intel® VT-x with Extended Page Tables (EPT)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="375358423" Local_ID="0" Value="Y" CategoryFeature_ID="134984" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="14803">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234849" langid="14" Value="Intel® TSX-NI"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="375717823" Local_ID="0" Value="Y" CategoryFeature_ID="135037" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="15741">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234771" langid="14" Value="Intel® 64"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="377211991" Local_ID="0" Value="Y" CategoryFeature_ID="135110" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Tak" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21759">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234857" langid="14" Value="Technologia virtualizacji Intel® (VT-x)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="378463642" Local_ID="0" Value="193384" CategoryFeature_ID="176718" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="193384" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="193384">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="27646">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2884892" langid="14" Value="Procesor ARK ID"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942083" Local_ID="0" Value="Y" CategoryFeature_ID="26567" CategoryFeatureGroup_ID="1056" No="10100200" Optional="0" Presentation_Value="Tak" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Tak">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3247">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="518402" langid="14" Value="Obsługa zasilania zapasowego (RPS)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942082" Local_ID="0" Value="550" CategoryFeature_ID="4718" CategoryFeatureGroup_ID="1056" No="100095" Optional="0" Presentation_Value="550 W" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="550">
    <Measure ID="44">
     <Signs>
      <Sign ID="7617" langid="14"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1242">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="7617" langid="14"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519833" langid="14" Value="Zasilanie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858396" Local_ID="0" Value="2" CategoryFeature_ID="595335" CategoryFeatureGroup_ID="1056" No="99990" Optional="0" Presentation_Value="2 m" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="54">
     <Signs>
      <Sign ID="7626" langid="14"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="8164">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="7626" langid="14"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1076805" langid="14" Value="Długość kabla zasilającego"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858450" Local_ID="0" Value="C13 coupler" CategoryFeature_ID="595336" CategoryFeatureGroup_ID="1056" No="99989" Optional="0" Presentation_Value="C13 panel" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="C13 panel">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="42458">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7437610" langid="14" Value="Złącze kabla zasilającego 1"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858447" Local_ID="0" Value="C14 coupler" CategoryFeature_ID="595337" CategoryFeatureGroup_ID="1056" No="99988" Optional="0" Presentation_Value="C14 panel" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="C14 panel">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="42459">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7437611" langid="14" Value="Złącze kabla zasilającego 2"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="414858400" Local_ID="0" Value="10" CategoryFeature_ID="595338" CategoryFeatureGroup_ID="1056" No="99987" Optional="0" Presentation_Value="10 A" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10">
    <Measure ID="41">
     <Signs>
      <Sign ID="7614" langid="14"><![CDATA[A]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="42457">
    <Measure ID="41" Sign="">
     <Signs>
      <Sign ID="7614" langid="14"><![CDATA[A]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7437609" langid="14" Value="Prąd kabla zasilającego"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942086" Local_ID="0" Value="10 - 35" CategoryFeature_ID="4441" CategoryFeatureGroup_ID="2698" No="100045" Optional="0" Presentation_Value="10 - 35 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 35">
    <Measure ID="65">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519797" langid="14" Value="Zakres temperatur (eksploatacja)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942087" Local_ID="0" Value="-40 - 65" CategoryFeature_ID="1777" CategoryFeatureGroup_ID="2698" No="100044" Optional="0" Presentation_Value="-40 - 65 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-40 - 65">
    <Measure ID="65">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="7637" langid="14"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519631" langid="14" Value="Zakres temperatur (przechowywanie)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942088" Local_ID="0" Value="10 - 80" CategoryFeature_ID="1277" CategoryFeatureGroup_ID="2698" No="100035" Optional="0" Presentation_Value="10 - 80%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 80">
    <Measure ID="64">
     <Signs>
      <Sign ID="7636" langid="14"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="7636" langid="14"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519622" langid="14" Value="Zakres wilgotności względnej"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362942090" Local_ID="0" Value="5 - 95" CategoryFeature_ID="12224" CategoryFeatureGroup_ID="2698" No="100033" Optional="0" Presentation_Value="5 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="7636" langid="14"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="7636" langid="14"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519857" langid="14" Value="Dopuszczalna wilgotność względna"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943368" Local_ID="0" Value="42.8" CategoryFeature_ID="6244" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="42,8 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="42,8">
    <Measure ID="24">
     <Signs>
      <Sign ID="7600" langid="14"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1464">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="7600" langid="14"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="519869" langid="14" Value="Wysokość produktu"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="362943369" Local_ID="0" Value="AC" CategoryFeature_ID="56948" CategoryFeatureGroup_ID="7714" No="100000" Optional="1" Presentation_Value="Prąd przemienny" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Prąd przemienny">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1830">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="516195" langid="14" Value="Przewody"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/gallery_lows/8d66c83dd84757dcb71d2c8bb02932da19a3e8be.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6273" No="1" Original="https://images.icecat.biz/img/gallery_raw/dc8673cbfc750f4c5e549cddb9c1379cd002bb66.png" OriginalSize="3189290" Pic="https://images.icecat.biz/img/gallery/30e54be428d3f3b887168e02f8fd019fca54b3fe.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/8dedc29aa2bbcd20de21e9da23ec28febab08480.jpg" Pic500x500Height="500" Pic500x500Size="27782" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900134" Size="1772361" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/3278fc6f1f35fe7e35bb5bae2c376528f1b6b0b5.jpg" ThumbSize="1749" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/80286a0b87112875a73e3d9db2c931d3af8713b9.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6469" No="2" Original="https://images.icecat.biz/img/gallery_raw/f7cbc4e199adf121c5bc9638ea71677fa645d758.png" OriginalSize="3299879" Pic="https://images.icecat.biz/img/gallery/740e455495117c7e60e66a29024ba2c52185d590.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/69cc06d3dbf1a0e25a5665d05fb801b1fa14639b.jpg" Pic500x500Height="500" Pic500x500Size="30729" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900139" Size="1820010" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/1b56923771c191de34c1f1214e4aa37daa4b9e73.jpg" ThumbSize="1772" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/80f107757247f276123983d97d3d44ac658d93bc.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="10105" No="3" Original="https://images.icecat.biz/img/gallery_raw/6bb1e99b1993054a1f43672c2742f4176cb4a7d2.png" OriginalSize="6903005" Pic="https://images.icecat.biz/img/gallery/3a7a959fba4c621acca2c6b73ea1889e1c44f2ff.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/aa7cfdb0dcab2f08d85179a821ac924d893782b9.jpg" Pic500x500Height="500" Pic500x500Size="47264" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900144" Size="3372621" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/036271f0a7957e2d5759c1773dde558e55310e74.jpg" ThumbSize="2426" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/a9a6855fc61544c2ad05bf344312c071b8929c6a.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6270" No="4" Original="https://images.icecat.biz/img/gallery_raw/6535d0bbfe7e93d41b0646134da4ef4044e1fda3.png" OriginalSize="2377360" Pic="https://images.icecat.biz/img/gallery/9aac0bda3411c41b0a94a5f252215d72e0b67ed5.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/a58c0f51875fe9c02ee8f239eb2eaf9b9bc6b76a.jpg" Pic500x500Height="500" Pic500x500Size="30096" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900154" Size="1639665" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/f2a10a88bc6bc6352df6176f0798f25bb2f27b0b.jpg" ThumbSize="1864" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/8141710ee426050c1b0c14dc098d3314ccb2b1bb.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6469" No="5" Original="https://images.icecat.biz/img/gallery_raw/2c40329f4dda530e0eaa161fb88bfb65493d5760.png" OriginalSize="3315239" Pic="https://images.icecat.biz/img/gallery/5e845ab2122270747fde96411bd4660a16343a08.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/070aba245d1e83e63df32ae1cff4cb8ba1563aa5.jpg" Pic500x500Height="500" Pic500x500Size="31084" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900155" Size="1822189" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/4548273f1fa251b240c74440ec925d90631dfe7c.jpg" ThumbSize="1756" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/9e05bffabbf5f756d56d9429f6fb232c1ef13d44.jpg" LowPicHeight="200" LowPicWidth="200" LowSize="6260" No="6" Original="https://images.icecat.biz/img/gallery_raw/3e1c2bf9dd79b861b7490968ab56ae5c93a21ff3.png" OriginalSize="3212067" Pic="https://images.icecat.biz/img/gallery/1602e68798c1693e850a54068095a3026bfc95ee.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/6b6fb51b93eb7f7d90451dc25038663a250b6320.jpg" Pic500x500Height="500" Pic500x500Size="27512" Pic500x500Width="500" PicHeight="5000" PicWidth="5000" ProductPicture_ID="119900159" Size="1777119" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/04f1b4815949506a2a042b91a06859ac85b12569.jpg" ThumbSize="1772" Type="ProductImage" UpdatedDate="2025-10-08 17:11:52"/>
   <ProductPicture LowPic="" LowPicHeight="0" LowPicWidth="0" LowSize="0" No="999" Original="" OriginalSize="0" Pic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Pic500x500="" Pic500x500Height="0" Pic500x500Size="0" Pic500x500Width="0" PicHeight="0" PicWidth="0" ProductPicture_ID="4309949491" Size="0" ThumbPic="https://images.icecat.biz/img/feature_logo_thumbs/1498-1295.png" ThumbSize="0" Type="FeatureLogo" UpdatedDate="" langid="14"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2025-09-29 13:05:12" Description="Dell EMC PowerEdge R440 Podręcznik Wprowadzenie" KeepAsURL="0" MultimediaObject_ID="69889024" Type="other digital assets" UUID="ED39900B-F12B-45D7-9C7A-A2E7182B7A8B" langid="14" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="560187" URL="https://objects.icecat.biz/objects/mmo_80305432_1759143912_481_3126015.pdf" Width="0"/>
   <MultimediaObject ContentType="application/pdf" Date="2025-10-08 16:17:45" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="14" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=80305432&amp;lang=pl" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="14">DELL PowerEdge R440, 2,4 GHz, 4210R, 16 GB, DDR4-SDRAM, 480 GB, Rack (1U)</ShortSummaryDescription>
   <LongSummaryDescription langid="14">DELL PowerEdge R440. Typ procesora: Intel® Xeon Silver, Taktowanie procesora: 2,4 GHz, Model procesora: 4210R. Pamięć wewnętrzna: 16 GB, Typ pamięci wewnętrznej: DDR4-SDRAM, Układ pamięci: 1 x 16 GB. Całkowita pojemność przechowywania: 480 GB. Przewodowa sieć LAN, Technologia okablowania: 10/100/1000Base-T(X). Napędy optyczne: DVD-RW. Zasilanie: 550 W, Obsługa zasilania zapasowego (RPS). Obudowa: Rack (1U)</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="292" Name="DELL"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/da7186b6-167a-42d5-b7b0-19fa4548bc89" URL="https://coc.icecat.biz/da7186b6-167a-42d5-b7b0-19fa4548bc89"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
