<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 1-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/brand/high/5095_1ff9f8ebfb0f4c429c89242bc547cd55.jpg" HighPicHeight="400" HighPicSize="179216" HighPicWidth="2218" ID="24804254" LowPic="https://images.icecat.biz/img/brand/low/5095_a2f886d2a7e34643b05540b5641ceb50.jpg" LowPicHeight="36" LowPicSize="14144" LowPicWidth="200" Name="560931" IntName="560931" LocalName="" Pic500x500="https://images.icecat.biz/img/brand/medium/5095_cb97ed7fe68a4069b07970902d81989b.jpg" Pic500x500Height="90" Pic500x500Size="41333" Pic500x500Width="500" Prod_id="560931" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/img/brand/thumb/5095_5cfa86ad970840cf8e1fc259868651a1.jpg" ThumbPicSize="4365" Title="Intellinet 560931 network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) 1U Black" GeneratedIntTitle="Intellinet 560931 network switch" GeneratedLocalTitle="Intellinet 560931 network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) 1U Black" BrandLocalTitle="">
  <CategoryFeatureGroup ID="31974" No="0">
   <FeatureGroup ID="0">
    <Name ID="5073" langid="1" Value="Technical details"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="763" No="195">
   <FeatureGroup ID="12">
    <Name ID="4995" langid="1" Value="Ports &amp; interfaces"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1144" No="135">
   <FeatureGroup ID="14">
    <Name ID="5023" langid="1" Value="Weight &amp; dimensions"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1142" No="150">
   <FeatureGroup ID="27">
    <Name ID="5049" langid="1" Value="Power"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1143" No="140">
   <FeatureGroup ID="28">
    <Name ID="5067" langid="1" Value="Operational conditions"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2987" No="165">
   <FeatureGroup ID="34">
    <Name ID="5139" langid="1" Value="Protocols"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1141" No="190">
   <FeatureGroup ID="35">
    <Name ID="5167" langid="1" Value="Network"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2484" No="180">
   <FeatureGroup ID="62">
    <Name ID="27261" langid="1" Value="Data transmission"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2483" No="125">
   <FeatureGroup ID="67">
    <Name ID="27423" langid="1" Value="Packaging data"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2482" No="175">
   <FeatureGroup ID="75">
    <Name ID="27867" langid="1" Value="Security"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="41469" No="0">
   <FeatureGroup ID="76">
    <Name ID="28540" langid="1" Value="Certificates"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2944" No="200">
   <FeatureGroup ID="93">
    <Name ID="30784" langid="1" Value="Management features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="49104" No="130">
   <FeatureGroup ID="116">
    <Name ID="78852" langid="1" Value="Packaging content"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="5713" No="185">
   <FeatureGroup ID="137">
    <Name ID="593565" langid="1" Value="Optical fiber"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53530" No="0">
   <FeatureGroup ID="143">
    <Name ID="618812" langid="1" Value="Battery"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8343" No="144">
   <FeatureGroup ID="146">
    <Name ID="624346" langid="1" Value="Other features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10881" No="160">
   <FeatureGroup ID="148">
    <Name ID="630457" langid="1" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="9999" No="145">
   <FeatureGroup ID="174">
    <Name ID="1099151" langid="1" Value="Power over Ethernet (PoE)"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10882" No="155">
   <FeatureGroup ID="184">
    <Name ID="1218765" langid="1" Value="Performance"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="70398" No="0">
   <FeatureGroup ID="185">
    <Name ID="1219853" langid="1" Value="Features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="24990" No="-100">
   <FeatureGroup ID="198">
    <Name ID="1788927" langid="1" Value="Logistics data"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="60022" No="0">
   <FeatureGroup ID="232">
    <Name ID="3464238" langid="1" Value="Supplier features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="27921" No="170">
   <FeatureGroup ID="252">
    <Name ID="4234027" langid="1" Value="Multicast features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76178" No="120">
   <FeatureGroup ID="279">
    <Name ID="7392238" langid="1" Value="Sustainability"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77984" No="0">
   <FeatureGroup ID="305">
    <Name ID="8837290" langid="1" Value="Carbon footprint"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="258">
   <Name ID="3727481" langid="1" Value="Network Switches"/>
  </Category>
  <EANCode/>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Managed L2 Web-based management SNMP V1, V2, V3" langid="1" No="1"/>
   <GeneratedBulletPoint Value="Quality of Service (QoS) support" langid="1" No="2"/>
   <GeneratedBulletPoint Value="Basic switching RJ-45 Ethernet ports quantity: 16" langid="1" No="3"/>
   <GeneratedBulletPoint Value="Cat5, Cat5e 10BASE-T, 100BASE-TX, 1000BASE-T" langid="1" No="4"/>
   <GeneratedBulletPoint Value="MAC address table: 8000 entries Switching capacity: 36 Gbit/s" langid="1" No="5"/>
   <GeneratedBulletPoint Value="1U Rack mounting" langid="1" No="6"/>
   <GeneratedBulletPoint Value="Power over Ethernet (PoE)" langid="1" No="7"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription ID="46231100" LongDesc="&lt;b&gt;Save installation time and money with PoE&lt;/b&gt;&lt;br&gt;&lt;br&gt;The Intellinet 16-Port Gigabit Ethernet PoE+ Web-Managed Switch with 2 SFP Ports (560931) is designed to pass both data and electrical power to a number of PoE-compatible devices via standard Cat5e or Cat6 network cables. Equipped with sixteen Gigabit Ethernet ports, all of which support 802.3at/af Power over Ethernet (PoE/PoE+), this switch can power Wireless LAN access points and bridges, VoIP (Voice over Internet Protocol) telephones, IP surveillance cameras and more while delivering network speeds of up to 1,000 Mbps.&lt;br&gt;&lt;br&gt;&lt;b&gt;Power over Ethernet 802.3at&lt;/b&gt;&lt;br&gt;&lt;br&gt;The Intellinet 16-Port Gigabit Ethernet PoE+ Web-Managed Switch with 2 SFP Ports supports the IEEE 802.3at protocol and is designed to inject up to 30 watts of power per port*. IEEE802.3af or IEEE802.3at compliant devices attached to the switch require no additional power, thus eliminating the time and expense of electrical rewiring and minimizing the unsightly clutter caused by power supplies and adapters in awkward places such as ceilings and walls. Any mix of PoE and non-PoE devices is supported, and thanks to its short circuit, overload and high-voltage protection function, your equipment is well-protected. For devices that are not 802.3at/af compliant (legacy wireless access points or network cameras), we suggest use of an Intellinet PoE/PoE+ Splitter.&lt;br&gt;&lt;br&gt;&lt;b&gt;Eliminate Bottlenecks with Gigabit Speeds&lt;/b&gt;&lt;br&gt;&lt;br&gt;Equipped with 16 auto-sensing 10/100/1000 Mbps RJ45 Gigabit Ethernet ports, the 16-Port PoE Web-Managed Desktop Gigabit Switch (560931) offers plenty of performance for your computers, servers and other networking devices. In addition, two small form-factor pluggable GBIC module slots (SFP) provide fiber connectivity for greater distances.&lt;br&gt;&lt;br&gt;&lt;b&gt;Full Layer 2+ Management Features&lt;/b&gt;&lt;br&gt;&lt;br&gt;The switch includes full Layer 2+ Management features. The software set includes up to 4k 802.1Q VLAN and advanced protocol VLAN, private VLAN and MVR. There are eight physical Quality of Service queues, IPv4/v6 Multicast filtering, Rapid Spanning Tree Protocol to avoid network loop, Multiple Spanning Tree Protocol to integrate VLAN and spanning tree, LACP, LLDP; sFlow, port mirroring, cable diagnostic and advanced network security features. It also provides Console CLI for out-of-band management and SNMP, Web GUI for in-band management.&lt;br&gt;&lt;br&gt;&lt;b&gt;Advanced Security&lt;/b&gt;&lt;br&gt;&lt;br&gt;The Intellinet 16-Port PoE+ Web-Managed Desktop Gigabit Switch (560931) supports advanced security features. For secure switch management, HTTPS and SSH are provided. In addition, the login password and configuration packets are secured. Port binding allows to bind a specific MAC address to a port, and then only that MAC has the privilege to access the network. Thanks to 802.1X port based access control, every user needs to be authorized first when they want to access the network. AAA stands for Authentication, Authorization and Accounting with RADIUS, TACAS+ server. The Layer 2+ access control list (ACL) allows the user to define the access privilege based on IP, MAC address or Port number." ManualPDFSize="18910596" ManualPDFURL="https://objects.icecat.biz/objects/mmo_24804254_1464106660_238_16810.pdf" MiddleDesc="" PDFSize="465988" PDFURL="https://objects.icecat.biz/objects/mmo_24804254_1464106644_2865_12367.pdf" ShortDesc="16-Port Gigabit Ethernet PoE+ Web-Managed Switch w / 2 SFP Ports" URL="http://www.intellinet-network.com/search?q=560931" WarrantyInfo="" langid="1"/>
  <ProductFeature Localized="0" ID="214628303" Local_ID="0" Value="Managed" CategoryFeature_ID="20904" CategoryFeatureGroup_ID="2944" No="10100150" Optional="0" Presentation_Value="Managed" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Managed">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3769">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="42614" langid="1" Value="Switch type"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628445" Local_ID="0" Value="L2" CategoryFeature_ID="18586" CategoryFeatureGroup_ID="2944" No="100111" Optional="0" Presentation_Value="L2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="L2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3241">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30778" langid="1" Value="Switch layer"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628497" Local_ID="0" Value="Y" CategoryFeature_ID="18587" CategoryFeatureGroup_ID="2944" No="100010" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3242">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30790" langid="1" Value="Quality of Service (QoS) support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628333" Local_ID="0" Value="Y" CategoryFeature_ID="20768" CategoryFeatureGroup_ID="2944" No="100001" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3635">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="40000" langid="1" Value="Web-based management"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628313" Local_ID="0" Value="16" CategoryFeature_ID="86090" CategoryFeatureGroup_ID="763" No="10100100" Optional="0" Presentation_Value="16" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13503">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098928" langid="1" Value="Basic switching RJ-45 Ethernet ports quantity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628318" Local_ID="0" Value="Gigabit Ethernet (10/100/1000)" CategoryFeature_ID="86091" CategoryFeatureGroup_ID="763" No="10100099" Optional="0" Presentation_Value="Gigabit Ethernet (10/100/1000)" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="Gigabit Ethernet (10/100/1000)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13502">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098884" langid="1" Value="Basic switching RJ-45 Ethernet ports type"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628320" Local_ID="0" Value="0" CategoryFeature_ID="86092" CategoryFeatureGroup_ID="763" No="100090" Optional="0" Presentation_Value="0" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13501">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098840" langid="1" Value="Installed SFP modules quantity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628324" Local_ID="0" Value="0" CategoryFeature_ID="86093" CategoryFeatureGroup_ID="763" No="100089" Optional="0" Presentation_Value="0" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13500">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098796" langid="1" Value="Installed SFP+ modules quantity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628326" Local_ID="0" Value="16" CategoryFeature_ID="20905" CategoryFeatureGroup_ID="763" No="100097" Optional="0" Presentation_Value="16" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3770">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="42631" langid="1" Value="Gigabit Ethernet (copper) ports quantity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="535379822" Local_ID="0" Value="2" CategoryFeature_ID="152578" CategoryFeatureGroup_ID="763" No="100060" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="24681">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2040193" langid="1" Value="SFP module slots quantity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628472" Local_ID="0" Value="IEEE 802.1D,IEEE 802.1Q,IEEE 802.1p,IEEE 802.1w,IEEE 802.1x,IEEE 802.3,IEEE 802.3ab,IEEE 802.3af,IEEE 802.3at,IEEE 802.3az,IEEE 802.3u,IEEE 802.3x" CategoryFeature_ID="45644" CategoryFeatureGroup_ID="1141" No="100999" Optional="0" Presentation_Value="IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1802">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5587" langid="1" Value="Networking standards"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628382" Local_ID="0" Value="N" CategoryFeature_ID="42644" CategoryFeatureGroup_ID="1141" No="100998" Optional="0" Presentation_Value="No" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="No">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7364">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="513539" langid="1" Value="10G support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628325" Local_ID="0" Value="10BASE-T,100BASE-TX,1000BASE-T" CategoryFeature_ID="2027" CategoryFeatureGroup_ID="1141" No="100099" Optional="0" Presentation_Value="10BASE-T, 100BASE-TX, 1000BASE-T" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10BASE-T, 100BASE-TX, 1000BASE-T">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7659">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="593415" langid="1" Value="Copper ethernet cabling technology"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628767" Local_ID="0" Value="Cat5,Cat5e" CategoryFeature_ID="125278" CategoryFeatureGroup_ID="1141" No="100050" Optional="0" Presentation_Value="Cat5, Cat5e" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Cat5, Cat5e">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="8129">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="627921" langid="1" Value="Cable types supported"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628491" Local_ID="0" Value="Y" CategoryFeature_ID="18588" CategoryFeatureGroup_ID="1141" No="100005" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3243">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30796" langid="1" Value="Port mirroring"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628506" Local_ID="0" Value="Y" CategoryFeature_ID="2042" CategoryFeatureGroup_ID="1141" No="100002" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="536">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2603" langid="1" Value="Full duplex"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628492" Local_ID="0" Value="Y" CategoryFeature_ID="16314" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2756">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="13950" langid="1" Value="Flow control support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628490" Local_ID="0" Value="Y" CategoryFeature_ID="18589" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3244">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30802" langid="1" Value="Link aggregation"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628772" Local_ID="0" Value="Y" CategoryFeature_ID="18892" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3324">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="31786" langid="1" Value="Broadcast storm control"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628773" Local_ID="0" Value="Y" CategoryFeature_ID="20900" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3764">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="42509" langid="1" Value="Rate limiting"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628477" Local_ID="0" Value="Y" CategoryFeature_ID="33013" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6566">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="223512" langid="1" Value="Auto MDI/MDI-X"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628501" Local_ID="0" Value="Y" CategoryFeature_ID="33015" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6568">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="223562" langid="1" Value="Spanning tree protocol"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628364" Local_ID="0" Value="Y" CategoryFeature_ID="86096" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13504">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1098972" langid="1" Value="Auto-sensing"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214630068" Local_ID="0" Value="Y" CategoryFeature_ID="114582" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="17494">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1244352" langid="1" Value="Auto-negotiation"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628371" Local_ID="0" Value="Y" CategoryFeature_ID="58638" CategoryFeatureGroup_ID="1141" No="99999" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7157">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="348192" langid="1" Value="VLAN support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628869" Local_ID="0" Value="Private VLAN,Tagged VLAN,Port-based VLAN" CategoryFeature_ID="306825" CategoryFeatureGroup_ID="1141" No="99998" Optional="0" Presentation_Value="Private VLAN, Tagged VLAN, Port-based VLAN" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Private VLAN, Tagged VLAN, Port-based VLAN">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="38464">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5356588" langid="1" Value="Virtual LAN features"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628872" Local_ID="0" Value="4096" CategoryFeature_ID="33014" CategoryFeatureGroup_ID="1141" No="99997" Optional="0" Presentation_Value="4096" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4096">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6567">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="223537" langid="1" Value="Number of VLANs"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628512" Local_ID="0" Value="8000" CategoryFeature_ID="2026" CategoryFeatureGroup_ID="2484" No="10100086" Optional="0" Presentation_Value="8000 entries" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="8000">
    <Measure ID="56">
     <Signs>
      <Sign ID="39" langid="1"><![CDATA[entries]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="566">
    <Measure ID="56" Sign="">
     <Signs>
      <Sign ID="39" langid="1"><![CDATA[entries]]></Sign>
     </Signs>
    </Measure>
    <Name ID="2663" langid="1" Value="MAC address table"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629068" Local_ID="0" Value="36" CategoryFeature_ID="11205" CategoryFeatureGroup_ID="2484" No="100090" Optional="0" Presentation_Value="36 Gbit/s" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="36">
    <Measure ID="68">
     <Signs>
      <Sign ID="51" langid="1"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1801">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="51" langid="1"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="5585" langid="1" Value="Switching capacity"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629219" Local_ID="0" Value="26.8" CategoryFeature_ID="86124" CategoryFeatureGroup_ID="2484" No="100089" Optional="0" Presentation_Value="26.8 Mpps" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="26.8">
    <Measure ID="196">
     <Signs>
      <Sign ID="9269" langid="1"><![CDATA[Mpps]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="13516">
    <Measure ID="196" Sign="">
     <Signs>
      <Sign ID="9269" langid="1"><![CDATA[Mpps]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1099637" langid="1" Value="Throughput"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628504" Local_ID="0" Value="Y" CategoryFeature_ID="20896" CategoryFeatureGroup_ID="2484" No="100080" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3760">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="42431" langid="1" Value="Store-and-forward"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629109" Local_ID="0" Value="4" CategoryFeature_ID="19926" CategoryFeatureGroup_ID="2484" No="100032" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3508">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="33592" langid="1" Value="Number of queues"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628900" Local_ID="0" Value="Y" CategoryFeature_ID="18591" CategoryFeatureGroup_ID="2484" No="100020" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3246">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30814" langid="1" Value="Jumbo frames support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628908" Local_ID="0" Value="9000" CategoryFeature_ID="130953" CategoryFeatureGroup_ID="2484" No="100019" Optional="0" Presentation_Value="9000" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="9000">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21666">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1728430" langid="1" Value="Jumbo frames"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629365" Local_ID="0" Value="DHCP server,DHCP client" CategoryFeature_ID="307220" CategoryFeatureGroup_ID="2482" No="100055" Optional="0" Presentation_Value="DHCP server, DHCP client" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="DHCP server, DHCP client">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="38476">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5359339" langid="1" Value="DHCP features"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628774" Local_ID="0" Value="Y" CategoryFeature_ID="33011" CategoryFeatureGroup_ID="2482" No="100001" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6565">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="223487" langid="1" Value="IGMP snooping"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628487" Local_ID="0" Value="802.1x RADIUS,SSH-2" CategoryFeature_ID="18054" CategoryFeatureGroup_ID="2482" No="100000" Optional="0" Presentation_Value="802.1x RADIUS, SSH-2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="802.1x RADIUS, SSH-2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="454">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2439" langid="1" Value="Security algorithms"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629373" Local_ID="0" Value="Y" CategoryFeature_ID="130888" CategoryFeatureGroup_ID="2482" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21645">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1727270" langid="1" Value="Loop protection"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629371" Local_ID="0" Value="Y" CategoryFeature_ID="130889" CategoryFeatureGroup_ID="2482" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21646">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1727320" langid="1" Value="BPDU filtering/protection"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629366" Local_ID="0" Value="Guest VLAN,MAC-based authentication,Port-based authentication" CategoryFeature_ID="130933" CategoryFeatureGroup_ID="2482" No="100000" Optional="0" Presentation_Value="Guest VLAN, MAC-based authentication, Port-based authentication" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Guest VLAN, MAC-based authentication, Port-based authentication">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21657">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1727930" langid="1" Value="Authentication"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628329" Local_ID="0" Value="Y" CategoryFeature_ID="18594" CategoryFeatureGroup_ID="27921" No="100100" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3249">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="30832" langid="1" Value="Multicast support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629385" Local_ID="0" Value="8000" CategoryFeature_ID="86125" CategoryFeatureGroup_ID="27921" No="100075" Optional="0" Presentation_Value="8000" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8000">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13518">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1099725" langid="1" Value="Number of multicast groups filtered"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628475" Local_ID="0" Value="SNMP V1, V2, V3" CategoryFeature_ID="2036" CategoryFeatureGroup_ID="2987" No="119334" Optional="0" Presentation_Value="SNMP V1, V2, V3" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="SNMP V1, V2, V3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="502">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2535" langid="1" Value="Management protocols"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628480" Local_ID="0" Value="IPv4/v6" CategoryFeature_ID="19582" CategoryFeatureGroup_ID="2987" No="100000" Optional="0" Presentation_Value="IPv4/v6" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="IPv4/v6">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="557">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2645" langid="1" Value="Supported network protocols"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628446" Local_ID="0" Value="Y" CategoryFeature_ID="2038" CategoryFeatureGroup_ID="10881" No="10119336" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="483">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2497" langid="1" Value="Rack mounting"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628522" Local_ID="0" Value="1U" CategoryFeature_ID="2030" CategoryFeatureGroup_ID="10881" No="100095" Optional="0" Presentation_Value="1U" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1U">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="771">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="3073" langid="1" Value="Form factor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628447" Local_ID="0" Value="Black" CategoryFeature_ID="27196" CategoryFeatureGroup_ID="10881" No="100090" Optional="0" Presentation_Value="Black" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Black">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1766">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5487" langid="1" Value="Product colour"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628563" Local_ID="0" Value="Metal" CategoryFeature_ID="45641" CategoryFeatureGroup_ID="10881" No="100089" Optional="0" Presentation_Value="Metal" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Metal">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="5214">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="71767" langid="1" Value="Housing material"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628448" Local_ID="0" Value="Y" CategoryFeature_ID="7916" CategoryFeatureGroup_ID="10881" No="100079" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1501">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="4699" langid="1" Value="LED indicators"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="315994563" Local_ID="0" Value="Y" CategoryFeature_ID="306622" CategoryFeatureGroup_ID="10882" No="100099" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7787">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="601482" langid="1" Value="Built-in processor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629212" Local_ID="0" Value="416" CategoryFeature_ID="11189" CategoryFeatureGroup_ID="10882" No="100097" Optional="0" Presentation_Value="416 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="416">
    <Measure ID="18">
     <Signs>
      <Sign ID="9" langid="1"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="5">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="9" langid="1"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1291" langid="1" Value="Processor frequency"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629211" Local_ID="0" Value="128" CategoryFeature_ID="6909" CategoryFeatureGroup_ID="10882" No="100002" Optional="0" Presentation_Value="128 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="128">
    <Measure ID="19">
     <Signs>
      <Sign ID="15506" langid="1"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="6">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="15506" langid="1"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1295" langid="1" Value="Internal memory"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629209" Local_ID="0" Value="16" CategoryFeature_ID="14689" CategoryFeatureGroup_ID="10882" No="100001" Optional="0" Presentation_Value="16 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="19">
     <Signs>
      <Sign ID="15506" langid="1"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="538">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="15506" langid="1"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="2607" langid="1" Value="Flash memory"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214630058" Local_ID="0" Value="Y" CategoryFeature_ID="33010" CategoryFeatureGroup_ID="10882" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="4252">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="59871" langid="1" Value="Firmware upgradeable"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628515" Local_ID="0" Value="512" CategoryFeature_ID="109776" CategoryFeatureGroup_ID="10882" No="100000" Optional="1" Presentation_Value="512 KB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="512">
    <Measure ID="47">
     <Signs>
      <Sign ID="31" langid="1"><![CDATA[KB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1451">
    <Measure ID="47" Sign="">
     <Signs>
      <Sign ID="31" langid="1"><![CDATA[KB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="4559" langid="1" Value="Buffer size"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628795" Local_ID="0" Value="100 - 240" CategoryFeature_ID="63546" CategoryFeatureGroup_ID="1142" No="100145" Optional="0" Presentation_Value="100 - 240 V" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100 - 240">
    <Measure ID="42">
     <Signs>
      <Sign ID="26" langid="1"><![CDATA[V]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="8491">
    <Measure ID="42" Sign="">
     <Signs>
      <Sign ID="26" langid="1"><![CDATA[V]]></Sign>
     </Signs>
    </Measure>
    <Name ID="711418" langid="1" Value="AC input voltage"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628797" Local_ID="0" Value="50 - 60" CategoryFeature_ID="63547" CategoryFeatureGroup_ID="1142" No="100144" Optional="0" Presentation_Value="50 - 60 Hz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="50 - 60">
    <Measure ID="36">
     <Signs>
      <Sign ID="20" langid="1"><![CDATA[Hz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="8484">
    <Measure ID="36" Sign="">
     <Signs>
      <Sign ID="20" langid="1"><![CDATA[Hz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="711064" langid="1" Value="AC input frequency"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628791" Local_ID="0" Value="215" CategoryFeature_ID="114587" CategoryFeatureGroup_ID="1142" No="100089" Optional="0" Presentation_Value="215 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="215">
    <Measure ID="44">
     <Signs>
      <Sign ID="28" langid="1"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="9137">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="28" langid="1"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="762621" langid="1" Value="Power consumption (max)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214629081" Local_ID="0" Value="Y" CategoryFeature_ID="21078" CategoryFeatureGroup_ID="1142" No="99950" Optional="1" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1376">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="4293" langid="1" Value="Power management"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628465" Local_ID="0" Value="Over voltage,Overload,Short circuit" CategoryFeature_ID="132644" CategoryFeatureGroup_ID="1142" No="99950" Optional="0" Presentation_Value="Over voltage, Overload, Short circuit" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Over voltage, Overload, Short circuit">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7370">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="514076" langid="1" Value="Power protection features"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628460" Local_ID="0" Value="Y" CategoryFeature_ID="17380" CategoryFeatureGroup_ID="9999" No="10100098" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2988">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="28528" langid="1" Value="Power over Ethernet (PoE)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628463" Local_ID="0" Value="200" CategoryFeature_ID="86113" CategoryFeatureGroup_ID="9999" No="100000" Optional="0" Presentation_Value="200 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="200">
    <Measure ID="44">
     <Signs>
      <Sign ID="28" langid="1"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="13505">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="28" langid="1"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1099195" langid="1" Value="Total Power over Ethernet (PoE) budget"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628814" Local_ID="0" Value="0 - 40" CategoryFeature_ID="7827" CategoryFeatureGroup_ID="1143" No="100040" Optional="0" Presentation_Value="0 - 40 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 40">
    <Measure ID="65">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="3765" langid="1" Value="Operating temperature (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628819" Local_ID="0" Value="-20 - 90" CategoryFeature_ID="7830" CategoryFeatureGroup_ID="1143" No="100039" Optional="0" Presentation_Value="-20 - 90 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-20 - 90">
    <Measure ID="65">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="3045" langid="1" Value="Storage temperature (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628817" Local_ID="0" Value="10 - 90" CategoryFeature_ID="7825" CategoryFeatureGroup_ID="1143" No="100035" Optional="0" Presentation_Value="10 - 90%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 90">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="2937" langid="1" Value="Operating relative humidity (H-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628801" Local_ID="0" Value="330" CategoryFeature_ID="63548" CategoryFeatureGroup_ID="1144" No="100040" Optional="0" Presentation_Value="330 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="330">
    <Measure ID="24">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1649">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="5143" langid="1" Value="Width"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628804" Local_ID="0" Value="210" CategoryFeature_ID="63549" CategoryFeatureGroup_ID="1144" No="100030" Optional="0" Presentation_Value="210 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="210">
    <Measure ID="24">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1650">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="5145" langid="1" Value="Depth"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628805" Local_ID="0" Value="44" CategoryFeature_ID="63550" CategoryFeatureGroup_ID="1144" No="100020" Optional="0" Presentation_Value="44 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="44">
    <Measure ID="24">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1464">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="3" langid="1"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="4625" langid="1" Value="Height"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628809" Local_ID="0" Value="2500" CategoryFeature_ID="8713" CategoryFeatureGroup_ID="1144" No="100000" Optional="0" Presentation_Value="2.5 kg" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.5">
    <Measure ID="17">
     <Signs>
      <Sign ID="15505" langid="1"><![CDATA[kg]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="94">
    <Measure ID="38" Sign="">
     <Signs>
      <Sign ID="22" langid="1"><![CDATA[g]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1525" langid="1" Value="Weight"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628828" Local_ID="0" Value="AC,Serial" CategoryFeature_ID="19508" CategoryFeatureGroup_ID="49104" No="100050" Optional="0" Presentation_Value="AC, Serial" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="AC, Serial">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1830">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5653" langid="1" Value="Cables included"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628833" Local_ID="0" Value="Y" CategoryFeature_ID="63578" CategoryFeatureGroup_ID="49104" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3965">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="56040" langid="1" Value="Manual"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628524" Local_ID="0" Value="Y" CategoryFeature_ID="130955" CategoryFeatureGroup_ID="2483" No="100000" Optional="1" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="8850">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="746273" langid="1" Value="Mounting brackets included"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214628783" Local_ID="0" Value="FCC Class A, CE" CategoryFeature_ID="17378" CategoryFeatureGroup_ID="41469" No="99900" Optional="0" Presentation_Value="FCC Class A, CE" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="FCC Class A, CE">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="249">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1865" langid="1" Value="Certification"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/brand/low/5095_a2f886d2a7e34643b05540b5641ceb50.jpg" LowPicHeight="36" LowPicWidth="200" LowSize="14144" No="999" Original="https://images.icecat.biz/img/brand/original/5095_94c7a3c9b0b246f68a992691989e9bf4.jpg" OriginalSize="173798" Pic="https://images.icecat.biz/img/brand/high/5095_1ff9f8ebfb0f4c429c89242bc547cd55.jpg" Pic500x500="https://images.icecat.biz/img/brand/medium/5095_cb97ed7fe68a4069b07970902d81989b.jpg" Pic500x500Height="90" Pic500x500Size="41333" Pic500x500Width="500" PicHeight="400" PicWidth="2218" ProductPicture_ID="8589939685" Size="179216" ThumbPic="https://images.icecat.biz/img/brand/thumb/5095_5cfa86ad970840cf8e1fc259868651a1.jpg" ThumbSize="4365" Type="BrandLogo" UpdatedDate="2026-01-07 15:14:32"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2016-05-24 18:18:08" Description="" KeepAsURL="0" MultimediaObject_ID="2837877" Type="leaflet" UUID="7fb3e61a-4b5e-4247-b463-8fc7db545324" langid="1" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="465988" URL="https://objects.icecat.biz/objects/mmo_24804254_1464106644_2865_12367.pdf" Width="0"/>
   <MultimediaObject ContentType="application/pdf" Date="2016-05-24 18:18:08" Description="" KeepAsURL="0" MultimediaObject_ID="2837878" Type="manual pdf" UUID="b6b00188-fe9f-4cba-9ded-9f107e106a0c" langid="1" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="18910596" URL="https://objects.icecat.biz/objects/mmo_24804254_1464106660_238_16810.pdf" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="1">Intellinet 560931, Managed, L2, Gigabit Ethernet (10/100/1000), Power over Ethernet (PoE), Rack mounting, 1U</ShortSummaryDescription>
   <LongSummaryDescription langid="1">Intellinet 560931. Switch type: Managed, Switch layer: L2. Basic switching RJ-45 Ethernet ports type: Gigabit Ethernet (10/100/1000), Basic switching RJ-45 Ethernet ports quantity: 16. Full duplex. MAC address table: 8000 entries, Switching capacity: 36 Gbit/s. Networking standards: IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE.... Power over Ethernet (PoE). Rack mounting, Form factor: 1U</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="5095" Name="Intellinet"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/85b228f2-e790-4513-ba9a-9b0e947a60d0" URL="https://coc.icecat.biz/85b228f2-e790-4513-ba9a-9b0e947a60d0"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
